Solar Farm – 15 MW @ 33 kV (UKPN, UK)
Independent ANM curtailment analysis using time-series back-cast and queue attrition.
Power Systems • Software • Data
Proof of experience, delivered with clarity.
RenSolv brings together extensive project experience from across the renewables and power systems sector.
Examples represent recent projects and those reflecting broader experience of our team. Due to NDAs, we keep project names confidential and show the capacity (MW), voltage (kV) and what we did.
Independent ANM curtailment analysis using time-series back-cast and queue attrition.
Network rebuild and historical trace assessment to establish bankable curtailment outlook.
ANM curtailment modelling incorporating storage dispatch behaviour.
LMS curtailment study assessing constraint patterns with and without storage.
Full gridcode compliance: load flow, reactive capability, shortcircuit, antiislanding, FRT, model build/validation. Accepted by DSO/TSO; connection in progress.
Category B/C compliance: PCC impedance, load flow, FRT, LoM settings, model validation. All sites successfully connected.
Full G99 suite including load-flow, fault-level, P28, G5/5, FRT/FFCI, frequency response and dynamic voltage/reactive-power control.
Full G99, P28 and G5/4-1 compliance, FRT, FFCI, and frequency response.
G99 assessments covering load-flow, fault-level, P28, FRT, FFCL, and frequency-response.
HV electrical layout optioneering and reactive power strategy to meet Grid Code; HV equipment sizing and system design.
One-of-its-kind, load flow, dynamic simulations, and control philosophy for integrated wind + hydrogen production.
Operational philosophy for an islanded oil & gas platform connecting to onshore grid for green-power import.
Detailed availability and reliability assessment for offshore transmission system in the UK and Ireland.
Grid-code compliance: reactive capability, voltage/frequency response, stability and FRT under multiple contingencies.
Stability Pathfinder feasibility using EMT simulations to demonstrate system-strength, inertia, frequency-response and FRT capability of a grid-forming BESS.
Evaluated reactive-compensation requirements and Grid Code compliance.
Grid-code compliance studies covering reactive capability, frequency and active-power response, voltage stability, FRT and protection coordination.
Two-stage Grid Code and Power-Quality Feasibility and Compliance programme. Feasibility studies identified technical risks in G99/P28/G5/5 compliance and reactive-power or harmonic-filtering needs. Analyses included short-circuit, load-flow, reactive-capability, EMT voltage-change, flicker and harmonic-penetration studies, and dynamic tests for FRT, FFCL and voltage-control capability.
Representative experience delivered by RenSolv engineers across multiple markets, outside of RenSolv. Client names withheld for confidentiality; scope and ratings shown for context.
Reactive support from DER to mitigate high voltage on transmission; contingency and optimal VAR dispatch.
Stability analysis for islanded grid; frequency and voltage control strategies.
Impact of SVC, MSC and STATCOM on voltage stability and RoCoF was assessed through dynamic stability simulations.
Dynamic studies for black-start from distributed generation; islanding and resynchronisation.
Feasibility & compliance: G99, P28, G5/5, short-circuit, reactive capability; private-wire interface.
G99 study with G5/5 harmonic analysis and flicker indices per P28.
Grid-code package including reactive capability, stability and protection coordination.
Compliance studies covering voltage stability, harmonics, and control model validation.
EMT feasibility for stability pathfinder: system strength, inertia, frequency response and fault-ride through.
G99 compliance: load flow, short-circuit, FRT, FFCL, G5/5, P28, and dynamic control validation.
Stability and compliance studies for multiple UK/Ireland projects, including model verification.
Reactive power optimisation and voltage compliance in hybrid configurations.
Load flow, short-circuit, transient stability; series compensation optimisation.
Commutation-failure and stability studies for receiving-end grid.
Transmission integration studies: load flow, fault levels, and stability.
Connection feasibility, reactive compensation, and network upgrade design.
Reactive compensation and G99 envelope studies.
G99 RMS studies including FRT, voltage/frequency control, and model validation.
Grid application support, SLDs, and protection coordination.
Simplified compliance under G99 Type B/C thresholds.
HV layout optioneering, losses, and harmonic review; cable/transformer/filter concept design.
Reactive compensation sizing (SVC TCR/TSC), voltage control and operational philosophy.
Load flow, reactive power, losses, fault level, and RMS dynamics in DIgSILENT.
Cable damage and transformer thermal-life assessments (170 kV export cable).
ENA forms, connection applications, and DNO/TO engagement.
Finding new sites for connection, capacity headroom tracking, reinforcement review, and early-stage connection mapping.
SLDs, protection concepts, and control interfaces.
Substation short-lists with cost envelopes and reinforcement triggers.
Design and compliance review for lenders.
Redundancy, losses, and installation methodology technical review.
Reactive compensation, losses, and reliability.
Grid-agreement and schedule risk assessments.
Contingency, fault levels, breaker ratings, and motor-start voltage dip.
Fault level, power flow, protection and flicker analysis.
Operating modes for green-power import and grid-tie controls.
Protection sizing and transformer capacity reviews.
R&D leadership; granted patents (US 11914355, EP 4166955).
AI-based state estimation, multi-step contingency tool, and dynamic capability mapping.
Methodology and simulation framework for DER-based black-start.
Network-wide filter placement and compliance with G5/5 limits.